Last edited by JoJogami
Tuesday, July 21, 2020 | History

3 edition of Findings of petrographic investigations of embedded cylinder prestressed concrete pipe found in the catalog.

Findings of petrographic investigations of embedded cylinder prestressed concrete pipe

Findings of petrographic investigations of embedded cylinder prestressed concrete pipe

  • 249 Want to read
  • 1 Currently reading

Published by U.S. Dept. of the Interior, Bureau of Reclamation, Technical Service Center, Research and Laboratory Services Division, Applied Sciences Branch, Available from the National Technical Information Service in Denver, Colo, Springfield, Va .
Written in English

    Subjects:
  • Petrofabric analysis.,
  • Pipe, Concrete -- Testing.,
  • Tendons (Prestressed concrete) -- Evaluation.

  • Edition Notes

    Statementby James Hartwell.
    ContributionsUnited States. Bureau of Reclamation. Denver Office. Applied Sciences Branch.
    The Physical Object
    FormatMicroform
    Paginationiv, 51 p.
    Number of Pages51
    ID Numbers
    Open LibraryOL16999610M

    2,+ construction related standards from all 13 volumes of Section 4 of the Annual Book of ASTM Standards. Subjects include cement, lime, gypsum, concrete and aggregates, road and paving materials, roofing waterproofing, bituminous materials, concret pipe, masonry, thermal insulation, environmental acoustis, building seals and sealants, fire standards, dimension stone, soil and rock   Safety, Reliability, Risk and Life-Cycle Performance of Structures and Infrastructures contains the plenary lectures and papers presented at the 11th International Conference on STRUCTURAL SAFETY AND RELIABILITY (ICOSSAR, New York, NY, USA, June ), and covers major aspects of safety, reliability, risk and life-cycle performance of structures and /Deodatis-Ellingwood-Frangopol/p/book/

    Required properties: Required strength at time of test = to psi Age at test: 22 to 26 h Measured properties: 1 day compressive strength: +/â psi Test parameters: Number of strands per cylinder = 1 Number of cylinders per test = 6 Cylinder dimensions: standard steel pipe 3-in. diameter by in. long. Welded steel base plate The American Concrete Institute. Founded in and headquartered in Farmington Hills, Michigan, USA, the American Concrete Institute is a leading authority and resource worldwide for the development, dissemination, and adoption of its consensus-based standards, technical resources, educational programs, and proven expertise for individuals and organizations involved in concrete design

    SPIE Digital Library Proceedings. Proc. SPIE , Smart Structures and Materials Sensors and Smart Structures Technologies for Civil, Mechanical, and Aerospace Systems, pg (29 July ); doi: / the force required to pull a steel disc or ring, embedded in fresh concrete, against a circular counter pressure placed on the concrete surface concentric with the disc/ring. For hardened concrete, an expandable steel ring is used instead. This ring expands to fit a specially drilled hole and routed recessin the


Share this book
You might also like
letter to the Archbishop of Canterbury

letter to the Archbishop of Canterbury

Teachers pay

Teachers pay

memoir on the scientific character and researches of the late James Smithson, Esq., F.R.S.

memoir on the scientific character and researches of the late James Smithson, Esq., F.R.S.

Leisure services financial management

Leisure services financial management

Don Martin Boxed Set

Don Martin Boxed Set

review of the records of the Widows Society of Hartford, 1825-1892.

review of the records of the Widows Society of Hartford, 1825-1892.

The pocket encyclopaedia of plant galls incolour

The pocket encyclopaedia of plant galls incolour

library environment

library environment

touch ofspring

touch ofspring

Can we co-operate?

Can we co-operate?

guide to the Stanstead Historical Society Archives

guide to the Stanstead Historical Society Archives

Tea-time tempest

Tea-time tempest

AZ Greater Manchester street atlas.

AZ Greater Manchester street atlas.

Waterchild.

Waterchild.

Findings of petrographic investigations of embedded cylinder prestressed concrete pipe Download PDF EPUB FB2

Get this from a library. Findings of petrographic investigations of embedded cylinder prestressed concrete pipe. [James Hartwell; United States. Bureau of Reclamation.

Denver Office. Applied Sciences Branch.]   Findings of Petrographic Investigations of Embedded Cylinder Prestressed Concrete Pipe (September ); Order PB Historic Performance of Buried Water Pipe Lines (September ); Order PB Prestressed Concrete Pipe Failure Jordan Aqueduct, Reach 3 (July ); Order PB   contains a summary of the findings from Reclamation investigations.

KEY WORDS AND DOCUMENT ANALYSIS a. DESCRIPTORS--buried pipe1 pipeline1 corrosion1 prestressed1 concrete1 precast/ pipe failure1 cathodic protection1 defective wire1 hydrogen embrittlemenv b. IDENTIFIERS-Jordan Aqueduct Reach 3 embedded cylinder prestressed concrete pipe/ A concrete mixture of sand, cement, and small gravel is used to make the concrete from which the tubular concrete pipe is made.

The pipe is made of :// James Hartwell has written: 'Findings of petrographic investigations of embedded cylinder prestressed concrete pipe' -- subject(s): Concrete Pipe, Evaluation, Petrofabric analysis, Pipe, Concrete The prestressed concrete bridge girder shown in Fig.

spans m and supports a superimposed dead load G of 6 kN/m and a live load Q of 20 kN/m (excluding self-weight). A mm thick topping slab was cast over the top flange of the beams after full stressing.

The bridge is upgraded for HLPV resulting in an increase in the unfactored live loads applied to the :// These failures, some of which are prestressed concrete cylinder pipe (PCCP), also cost significant sums for repair and eventual pipeline replacement.

These failures can wash out parallel sanitary sewers, which present a public health problem due to the possible contamination of the drinking water supply, and can also destroy private property   humidity of the concrete, and the pH and temperature.

3 Types and Causes of Concrete Deterioration Fig. Deicing salts are a major cause of corrosion of reinforcing steel in concrete. () Table 2. Maximum Chloride Ion Content of Concrete (ACI ) Maximum Type of Member Cl-* Prestressed concrete Reinforced concrete exposed to Mehdi S.

Zarghamee's 88 research works with citations and 3, reads, including: A Case Study on Design, Testing, and Installation of One of World’s Largest Subaqueous Pressure Pipelines ASTM's geotechnical engineering standards are instrumental in specifying, testing, and investigating the physical/mechanical properties and characteristic behaviors of surface and subsurface earth materials that are relevant to a construction :// Reinforced concrete cylinder pipes are similar to prestressed concrete pipes, except that there is no prestress and instead of using high tensile steel wire for circumferential reinforcement, carbon steel rod is used.

Size range is from mm to mm internal diameter with wall thicknesses from 78 mm to mm respectively, giving external See what's new with book lending at the Internet Archive. A line drawing of the Internet Archive headquarters building façade.

An illustration of a magnifying glass. An illustration of a magnifying glass. Full text of "ACI Building Code Requirements for Reinforced Concrete" diameter concrete pipe from production for the Gr eat Man-Made River, Libya (e.g.

Fookes et al.) in the s and s, to the concrete design for major gas production facilities in the A Standard Test Method for Hydrogen Embrittlement Resistance for Steel Wire Hard-Drawn Used for Prestressed Concrete Pipe. C/CM Standard Guide for Petrographic Examination of Aggregates for Concrete.

C Standard Test Method for Potential Alkali Reactivity of Carbonate Rocks as Concrete Aggregates (Rock-Cylinder Method) Additional information on PCCP can be found in "Performance of Prestressed Concrete Pipe" (American Water Works Association Research Foundation [AwwaRF], ), "Failure of Pre-Stressed Concrete Cylinder Pipe" (Romer et al, ), and several U.S.

Bureau of Reclamation reports on PCCP failures (Travers, ; Hartwell, ; Von Fay and Peabody ?Dockey= The prestressed concrete cylinder pipe (PCCP) North District Wastewater Treatment System in. Interceptor N-9 Force Main (FM), approximately five miles long, conveys wastewater along NW th Street to the MD-WASD Northwest District Wastewater Treatment facility.

The in. embedded PCCP portion of the pipeline was originally constructed QCS Contents Page 1 CONTENTS rw.l. l ta qa as se er ov o et it m SECTION 2 Part 1 Part 2 Part 3 Part 4 Part 5 Part 6 Part 7 Part 8 Part 9 Part 10 Part 11 Part 12 Part 13 Part 14 Part 15 Concrete for such walls shall be poured monolithically vertically unless otherwise provided in the plans or permitted in writing by the Engineer.

Concrete finish shall be in accordance with Revision of Section - Structural Concrete Coating and shall be required for the full height of the grooved pattern finish to one foot below ground :// Find + million publication pages, 20+ million researchers, and k+ projects. onAcademic is where you discover scientific knowledge and share your :// audio All audio latest This Just In Grateful Dead Netlabels Old Time Radio 78 RPMs and Cylinder Recordings.

Live Music Archive. Top Audio Books & Poetry Community Audio Computers, Full text of "First progress report of the investigation of prestressed reinforced concrete for highway bridges". C/CM Standard Guide for Petrographic Examination of Aggregates for Concrete C/CM Standard Specification for Asbestos-Cement Pressure Pipe C/CM Standard Test Method for Flatwise Tensile Strength of Sandwich ConstructionsInves- tigation of the concrete/strand interface included a study of the cement hydration at the strand interface, and a petrographic and chemical investigation of the strand/concrete interface in transfer length prisms in which poor bond was observed.

19 Change in Corr. Pot. (V) y = x + R2 = 0 An illustration of an open book. Books. An illustration of two cells of a film strip. Video. An illustration of an audio speaker. Audio. An illustration of a " floppy disk.

Full text of "Deterioration and REPAir of above Ground Concrete Water Tanks in Ontario, Canada"